BRT - REMOTE CONTROLLED ROOM

 

   

      

 

RADIOGRAPHY – FLUOROSCOPY TILTING TABLE

 

BRG.100R    High Frequency X-Ray generator for Radiography and Fluoroscopy

Radiographic data: 50 KW - 150 KV - 630 mA.

Anatomical program module. Minimum exposure time: 1 msec.

Microprocessor controlled unit. Tomography module

Output for one x-ray tube

Power supply: three phase 400/480 VAC.

Set low tension cables for interfacing with remote tables

Catalogue  ( pdf , 1711 kB)

CP2101 Support for generator control desk

CP2100 Exposure handswitch

 

 

BRT 20 Compact remote controle table             Catalogue  ( pdf ,1400 kB) 

Remote controlled tilting table, microprocessor controlled, for excellent

Radiography, Tomography and Fluoroscopy.

Includes a spot-film device which can accept a large size image intensifier up to 16".

Composition:

Examination table tilting from +90° to -18° Trendelenburg

Table top dimensions 210x74 cm, height from floor 82 cm.

Table top-film distance: 7,8 cm.

Automatic spot-film device suitable for x-ray cassettes from 18x24 to 35x43 cm.

Vertical subdivision into 2, 3 and 4 of all formats independently from cassette side used.

Grid 110 l/inch , Ratio 12:1 , focalization 120 cm

Preset to receive an automatic exposure control.

X-ray tube assembly with oblique incidences up to +/- 40° and rotation +/- 180° to enable examinations on uncoupled accessories.

Device for homethetic zonography and tomography in all tilting table positions.

Angles: 8°, 20° and 40°, two speeds each angle.

Layer height selection from 0 to 33 cm with millimetric variations.

Remote-controlled compression device.

Remote control console with commands for all operations and all radiographic, fluoroscopic,seriographic and tomographic techniques, visualised on digital display.

Complete of:

Motorized collimator .  Variable focus-film distance

Fixed I.I. support . Tabletop with transversal movement

Green carbonfiber concave tabletop

Grid . Adjustable footrest, Handgrips

 

BIS - 7TH Image Intensifier System with 7"/ 5" Thales I.I. tube

Automatic dose control with KV and mA adjustment.

CCD camera, one 17" TV monitor 100 Hz flicker free.

Digital memory with Last Image Hold.

 

Alternative to  I.I. model BIS 7 TH

BIS – 9TH Image Intensifier System with 9”/6”/4” Thales I.I. tube

Automatic dose control with KV and mA adjustment

CCD camera, one 17” TV monitor 100 Hz flicker free.

Digital memory with Last Image Hold

 

RTM 101 H HS-ray tube,focus 0.6-1.3 mm,20/50 KW,300 KHU with C52 housing

Catalogue  ( pdf , 911 kB)

 

Pair H.T. cables 12 mt. length

 

OPTIONS 

AEC interface with Ionization Chamber (ME2000)  

Trolley to support the TV monitor/s

Tabletop with longitudinal and transversal movement

Elevating I.I. suppor

Shoulder rest

Compression belt 

Motorized rotating footrest 

Support for glass of barium 

Head contention device

Pair of leg support 

Pair of ankle support

Lateral cassette holder 

Support for touch screen generator console

 

UPGRADE BRT 20 to DIGITAL ( BDG-CD)  for Angiography and DICOM III

 

BIS 9CD with 9" I.I. tube

Three fields 9”6”4” (22 – 16 – 11 cm) high contrast image

Intensifier model Thomson TH 9428 HP2 – H 542 complete of H.V power supply

Catalogue    ( pdf , 611 kB)

 

CD 1000 TV camera, 1Kx1k 10 bits CCD technique, progressive readout.

Remote controlled iris diaphragms

900 D dedicated one port optical distributor

Automatic saving of radiographic images on RAM and Hard disk

Manual saving of fluoroscopy images on RAM and Hard disk

- 24 images/sec in continuous fluoroscopy

- Up to 24 images/sec in pulsed fluoroscopy

- Up to 6 images/sec in radiography

17” (44 cm.) TV monitor with automatic brightness control

Main controller: 32 bits microprocessor for system interface controls

15 mt interconnecting cable

Photodiode automatic dose control (ABC + AEC)

Mechanical interface adapter,

 

BDG – CD Digital Spot Imaging

1kx1kx 10 bits digital processor

18 GB Hard Disc memory

40 MB RAM memory (29/60 images).

Electronic cabinet.

 

D.S.A.      Digital Substraction Angio

 

DICOM 3 interface suitable to send images to laser printerwith possibility

of multimages selection to be printed on same film (layout selection) It

includes printing software, LCD monitor and 15 mt interconnecting cables.

 

Other OPTIONS

GM1114 Detection chamber  

IB1100 Trolley to support the TV monitor/s  

I.I. 12’’ ( instead of 9’’)  

I.I. 16’’ ( instead of 9’’)  
x-ray tube RTM600H  (600 KHU ) instead of  RTM 101

ceiling system with rx tube E7252X , connecting cable 22 mt, lateral cassette holder  

 

 

 

 

CONVENTIONAL TILTING TABLE

BRG-200R   

High Frequency X-Ray generator for Radiography

Radiographic data: 50 KW - 125 KV - 600 mA.   Miin. exposure time: 1 msec.

Anatomical programming module   Microprocessor control unit.

 Output for one X-Ray tube.

Power supply: three phases 400/480 VAC.

Set of low tension cables for Bucky connections.

Catalogue  ( pdf , 1711 kB)

 

IM2001 BRAD

90°/13° tilting table for Radiography complete with rotating Column Stand

manual collimator and undertable 35x43 cm

Potter Bucky with vibrating grid R10 F100 34 l/cm.

 Fixed table top TO2004

Catalogue  ( pdf , 1711 kB)

 

E7252X Toshiba X-ray tube mode, focus 0.6-1.5 mm,

125 KV, 18/50 KW, 200 KHU, with housing.

Data sheet  ( pdf ,541 kB)

 

 

Pair H.T. cables 10 mt. Length

 

Alternative to table IM2001

IM2003 BRAD

90°/13° tilting table for Radiography complete with rotatingColumn Stand

manual collimator and undertable 35x43 cm.

Potter Bucky with vibrating grid R10 F100 34l/cm.

Four ways transversal moving table top.

    

 

                                    

 

 

 

 

C-arm mobile image intensifier

 

Catalogue  ( pdf , 1221 kB)          Data sheet  ( pdf , 735 kB)    

 

 

AT1001 Mobile stand with C-Arm model BCA-7

H.F. X-Ray Generator,max 110 KV - 65 mA, 40 KHz Inverter

Stationary anode X-Ray tube, dual focus 0.6 - 1.5 mm.

High sensitivity, compact, CCD camera, with image rotation device.

I.I. System with two fields 7"/5" high resolution I.I. tube.

Remote controlled iris collimator, X-Ray anti-diffusion grid.

Mobile trolley with one flicker free 17" TV monitor ( 100/120 Hz )

SBFM/1 Digital memory 576 x 576.Last Image Hold ( LIH ).

 

AT1002 Mobile C-arm model BCA-9 

H.F. X-Ray Generator,max 110 KV - 65 mA, 40 KHz Inverter

Stationary anode X-Ray tube, dual focus 0.6 - 1.5 mm.

High sensitivity, compact, CCD camera, with image rotation device.

I.I. System with three fields 9"/6"/4" high resolution I.I. tube.

Remote controlled iris collimator, X-Ray anti-diffusion grid.

Mobile trolley with one flicker free 17" TV monitor ( 100/120 Hz )

SBFM/1 Digital memory 576 x 576.Last Image Hold ( LIH ).

 

AT1003 Mobile Stand with C-arm, model BCA-R9 

H.F. X-Ray Generator,max 120 KV - 65 mA, 40 KHz Inverter.

Rotating anode X-Ray tube,dual focus 0.3 - 0.6 mm.

High sensitivity, compact, CCD camera, with image rotation device.

I.I. System with three fields 9"/6"/4" high resolution I.I. tube.

Remote controlled iris collimator, X-Ray anti-diffusion grid.

Mobile trolley with one flicker free 17" TV monitor ( 100/120 Hz )

SBFM/1 Digital memory 576 x 576.Last Image Hold ( LIH ).

 

AT1004 Mobile Stand with C-arm, model BCA-R 12 

H.F. X-Ray Generator,max 120 KV - 65 mA, 40 KHz Inverter.

Rotating anode X-Ray tube,dual focus 0.3 - 0.6 mm.

High sensitivity, compact, CCD camera, with image rotation device.

I.I. System with three fields 12"/9"/6" high resolution I.I. tube.

Remote controlled iris collimator, X-Ray anti-diffusion grid.

Mobile trolley with one flicker free 17" TV monitor ( 100/120 Hz )

SBFM/1 Digital memory 576 x 576.Last Image Hold ( LIH ).

 

 

Options

 

AT2000 Digital video memory

SBFM/4, 4+1, 4 images storage 

1 image on working monitor (left monitor) 4 images on the reference

monitor (right monitor). Second flicker free 17" TV monitor (100/120 Hz )

 

AT2004 Digital video memory

SBFM 36, for 110 images storage plus 1 Last Image Hold (LIH)

1 image on working monitor,110 images on reference monitor.

17" flicker free reference monitor (100/120Hz) as second monitor.

 

 

 

 

Back on X-ray home page

Retour sur la page principale radiologie

 

 


*                    MOBILE X-RAY MACHINES

*                    APPAREILS MOBILES DE RADIOLOGIE

 

*                    BRS  - BASIC  RADIOLOGY SYSTEM

*                    BRS - SYSTEME RADIOLOGIQUE DE BASE

 

Link Mobile X-ray machines and BUS systems

 

 

 


*  X-RAY CONVENTIONAL COLUMN/CEILING SYSTEMS

*  SYSTEMES RADIOLOGIE A COLONNE / PLAFOND

 

Link Conventional X-ray systems

 

 

 

 


*  DEVELOPING ACCESSORIES            

*  ACCESSOIRES POUR SALLE DE DEVELOPEMENT

 

Link Developping line

 

 

For downloading brochures , if you don’t have Acrobat Reader in your PC

Pour télédecharger les catalogues, si vous n’avez pas Acrobat Reader sur votre ordinateur

 

 

 

 

HOME PAGE